Return to index: [Subject] [Thread] [Date] [Author]
"Standard of Practice" for wood-frame earthquake retrofit tie-downs
[Subject Prev][Subject Next][Thread Prev][Thread Next]- To: <seaint(--nospam--at)seaint.org>
- Subject: "Standard of Practice" for wood-frame earthquake retrofit tie-downs
- From: "Thor Matteson" <thorm(--nospam--at)sti.net>
- Date: Thu, 11 Jun 2009 07:41:22 -0700
|
This is a question for SF Bay Area engineers who do residential or
light commercial earthquake retrofits for wood-framed buildings.
For cripple walls that are not very tall (say 18 inches or less), tie-down
installation becomes a problem. Most engineers will have some degree of
confidence that the self-weight of the building will resist overturning up to a
certain level, without doing extensive calculations to determine tributary
loads.
What calculated "raw" uplift (overturning moment/shear wall length,
ignoring self-weight) do you categorically ignore? 500
pounds? 750 pounds? 1000 pounds? Or do you
consider each case individually, and use your experience and judgment to decide
whether you need a tie-down to resist 751 pounds?
Feel free to e-mail me off-list. If I get enough off-list
responses to average, I will post the result with any highlights. I'm
counting on you, Ralph.... ;-)
Thanks,
Thor Matteson
|
- Prev by Subject: Re: "It's not in our culture"
- Next by Subject: Re: "Standard of Practice" for wood-frame earthquake retrofit tie-downs
- Previous by thread: Re: ASCE Presidential Election
- Next by thread: Re: "Standard of Practice" for wood-frame earthquake retrofit tie-downs