Return to index: [Subject] [Thread] [Date] [Author]
RE: 1.2 stress increase
[Subject Prev][Subject Next][Thread Prev][Thread Next]- To: <seaint(--nospam--at)seaint.org>
- Subject: RE: 1.2 stress increase
- From: "Yousefi, Ben" <Ben.Yousefi(--nospam--at)mountainview.gov>
- Date: Mon, 17 Nov 2008 12:03:16 -0800
- Disposition-notification-to: "Yousefi, Ben" <Ben.Yousefi(--nospam--at)mountainview.gov>
|
The only factor that is not allowed for
steel is the old 1.33 increase for short term wind and earthquake loading. The
1.2 factor is needed when using ASD load combination including Omega factor
since we have eliminated the old 1.7 factor (UBC). We now use 0.7 Ben Yousefi, SE, CBO From: Mark D. Baker
[mailto:shake4bake(--nospam--at)verizon.net] Per ASCE 7-05, when using equations with overstrength factor
(ASD), section 12.4.3.3 allows a 1.2 stress increase. I can’t find anywhere
in the code where this increase is disallowed for steel, including AISC 341. For some reason it is floating around in my brain that the
1.2 incr is not allowed for steel….am I imagining this? Regards, Mark D. Baker Baker Engineering |
Attachment:
oledata.mso
Description: oledata.mso
- Follow-Ups:
- RE: 1.2 stress increase
- From: Doug Mayer
- RE: 1.2 stress increase
- From: Mark D. Baker
- RE: 1.2 stress increase
- References:
- 1.2 stress increase
- From: Mark D. Baker
- 1.2 stress increase
- Prev by Subject: Re: 1.2 stress increase
- Next by Subject: RE: 1.2 stress increase
- Previous by thread: Re: 1.2 stress increase
- Next by thread: RE: 1.2 stress increase
- About this archive
- Messages sorted by: [Subject][Thread][Author][Date]