RE: 1 1/8" sht'g. diaphragm values
[Subject Prev][Subject Next][Thread Prev][Thread Next]- To: <seaint(--nospam--at)seaint.org>
- Subject: RE: 1 1/8" sht'g. diaphragm values
- From: "Tom Skaggs" <tom.skaggs(--nospam--at)apawood.org>
- Date: Thu, 29 Apr 2004 14:50:39 -0700
|
Diaphragm
table in building code states "minimum nominal panel thickness" (and requires
minimum nail penetration). So, for 1-1/8" sheathing, use either 15/32"
Str. I numbers or 19/32 sheathing numbers (turns out they are the same
numbers). And make sure nail is long enough to provide 1-1/2" penetration
(1-5/8" for older building codes).
Tom
-----------------------------------------------------------------------
From: Mark D. Baker [mailto:shake4bake(--nospam--at)earthlink.net] Sent: Thursday, April 29, 2004 14:13 To: seaint(--nospam--at)seaint.org Subject: 1 1/8" sht'g. diaphragm values Can anyone direct me to diaphragm shear values for 1 1/8" sht'g.?