Return to index: [Subject] [Thread] [Date] [Author]
Re:
[Subject Prev][Subject Next][Thread Prev][Thread Next]- To: seaint(--nospam--at)seaint.org
- Subject: Re:
- From: Daryl Richardson <h.d.richardson(--nospam--at)shaw.ca>
- Date: Thu, 24 Oct 2002 12:48:02 -0600
|
Thor,
The 1995 handbook page 525 lists specified strengths for fir and hem-fir (0.83 MPa) and for spruce-pine (0.51 MPa). Regards, H. Daryl Richardson
vicpeng wrote: I obviously haven't looked enough. Does anyone have an ideas for (allowable) tension across timber fibres (for DFir in this case)? Don't ask why I want that! I'm doing a "what if" or "how about" investigation that is taking me out to Mars and back :^) Thor A Tandy P.Eng, MIPENZ |