Return to index: [Subject] [Thread] [Date] [Author]
RE:
[Subject Prev][Subject Next][Thread Prev][Thread Next]- To: seaint(--nospam--at)seaint.org
- Subject: RE:
- From: "Peter McCormack" <PMac(--nospam--at)realloghomes.com>
- Date: Wed, 25 Oct 2000 15:02:22 -0400
- Priority: normal
Just in case, Australia uses a similar designation system.... UB is "universal beam" e.g: depth(mm)*width(mm)*mass(kg/meter) for example: 610x305x149UB the equivalent aussie universal beam is.... 610UB149 and the same convention for universal columns etc.... There is also a book by N.S. Trahair and M.A. Bradford "The Behaviour and Design of Steel Structures" which is useful to compare provisions of AISC LRFD with AS4100 and BS5950....a handy reference.. Peter McCormack